PosiTector Advanced Models
Revision Notes


 

ADV Base (PosiTector Advanced models - Serial Numbers: 864,000 and greater)

Revision Release Date Release Notes
8.05.105 14-Sept-2023 - PosiTector 6000 FNDS probes: Fixed possible batch display issue when storing duplex measurements in ISO 19840 mode
8.05.104 5-Sept-2023 - PosiTector 6000, PosiTector 200: Fixed issue with Prompted Batch Mode measurements when probe held on surface for repeated measurements
- PosiTector RTR 3D: Miscellaneous fixes
- Miscellaneous updates and fixes
8.05.101 23-Jan-2023 - PosiTector DPM: Alarm Temperature values can now be set over 100
- PosiTector UTG: Added Calibration Memory for storing additional materials
- Miscellaneous updates and fixes
8.05.99 8-Nov-2022 - PosiTector 6000: Added Strip Chart mode to Statistics mode. Press Up button when in Statistics mode to display Strip Chart.
- Fixed issue with enabling Memory when the clock is not set
- Added ability to disable audible reading tone (after successful measurement has been taken)
-Added new NMEA streaming format for USB Streaming
- Added AZERTY Keyboard Layout option for on-screen keyboard
- Miscellaneous updates and fixes
8.05.98 20-Oct-2022 - PosiTector RTR 3D probes: Added support for PosiTector RTR 3D probes with serial numbers greater than 1031196
- PosiTector SST probes: Increased maximum measurement range to 1700 μS/cm
-Added new NMEA streaming format for USB Streaming
- Added AZERTY Keyboard Layout option for on-screen keyboard
- Miscellaneous updates and fixes
8.05.97 14-Sept-2022 - Calibration adjustment information will now be reported when downloading measurements to PosiSoft
- PosiTector UTG P probes: Added Inch to the unit options
- Added Bluetooth classic support for Keyboard/Scanner input
- Miscellaneous updates and fixes
8.05.95 05-May-2022 - Added Reading Annotation support–add notes for each stored measurement using on screen keyboard, wireless Bluetooth BLE barcode scanner or keyboard
- Added support for Bluetooth BLE Barcode scanners and Keyboards—enter batch and reading annotations with ease
- Added user-selectable delimiter option for USB/Bluetooth Keyboard modes
- Miscellaneous updates and fixes
8.05.94 24-Mar-2022 - PosiTector 6000 probes: WiFi Streaming now includes statistics when using Statistics Scan
- Fixed PosiTector GLS sync issue with PosiSoft.net
- Miscellaneous updates and fixes
8.05.93 14-Mar-2022 - Added support for PosiTector GLS Gloss Meter probes
- Cal Lock ON/OFF state remains unchanged when a menu reset is performed
- Miscellaneous updates and fixes
8.05.90 10-Jan-2022 - Added support for Calibration Adjustment reporting for PosiSoft Desktop reports (requires PosiSoft Desktop v4.9.0+)
8.05.89 20-Dec-2021 - PosiTector 200: Added support for SSPC PA9
- PosiTector 200: Added support for storing multiple calibration adjustments
- PosiTector DPM L: Optimized downloading of large data logs from DPM L Smart Probe
- Miscellaneous updates and fixes
8.05.86 21-Jul-2021 - PosiTector UTG: Added support for Prompted Batches
- PosiTector RTR 3D: Increased SDF (Surface Data File) storage from 1 to 10 files
- Miscellaneous updates and fixes
8.05.85 14-Jun-2021 - PosiTector UTG C/CA/CX probes: Added Sensitivity adjustment feature
- Miscellaneous updates and fixes
8.05.84 7-Jun-2021 - PosiTector 6000 probes: Fix issue where creating a prompted batch without an image could cause gage to power down
- Miscellaneous updates and fixes
8.05.82 20-Apr-2021 - PosiTector 200: Added support for Prompted Batches
- Miscellaneous updates and fixes
8.05.81 8-Mar-2021 - Added Turkish support for On-Gage help
- Added Vietnamese support for Gage menu
- Miscellaneous updates and fixes
8.05.80 16-Feb-2021 - Added Italian language support for On-Gage Help
- Miscellaneous updates and fixes
8.05.79 10-Feb-2021 - Miscellaneous updates and fixes
8.05.78 5-Feb-2021 - Miscellaneous updates and fixes
8.05.77 23-Jan-2021 - Added Histogram to the batch view options
- Added user selectable power off time feature when connected via BLE Bluetooth Smart
- Miscellaneous updates and fixes

ADV Base (PosiTector Advanced models - Serial Numbers: 784,000 to 864,000)

Revision Release Date Release Notes
7.04.61 3-Aug-2020 - PosiTector RTR 3D probes: Now allows readings above 9999 for Spd 1/in2
- Miscellaneous updates and fixes
7.04.59 8-Feb-2020 - Fixed truncated interface which could occur when returning from Smart Probe menu
- Miscellaneous updates and fixes
7.04.58 20-Jan-2020 - Added Network Transfer Protocol for auto updating timezone for daylight savings time
- Miscellaneous updates and fixes
7.04.56 4-Dec-2019 - Added support for new PosiTector DPM L probe
7.04.55 21-Oct-2019 - Added ability to change default Access Point IP Address
7.04.54 26-Aug-2019 - IP addresses can now use DNS name
- Miscellaneous updates and fixes
7.04.53 13-Aug-2019 - Added ability to enter special characters in WiFi password field
- Miscellaneous updates and fixes
7.04.52 12-Aug-2019 - Added support for Prompted Batch Mode
- Miscellaneous updates and fixes
7.04.50 8-Jul-2019 - Updated keyboard for FTP Address field
- Miscellaneous updates and fixes
7.04.49 25-Jun-2019 - Added support for PosiTector UTG-P, UTG-CA, UTG-CLF probes
- Miscellaneous updates and fixes
7.04.48 22-May-2019 - Added WiFi Streaming support
- Miscellaneous updates and fixes
7.04.47 28-Feb-2019 - Increased Peak Count maximum to 99,999/in2 for PosiTector RTR 3D and PosiTector RTR P probes
7.04.46 23-Jan-2019 - Increased maximum measurement range for PosiTector 6000 FXS probe to 2000 microns (80 mils)
- Miscellaneous updates and fixes
7.04.44 7-Jan-2019 - Miscellaneous updates and fixes
7.04.43 2-Jan-2019 - Added support for PosiTector UTG M probes with serial number 355,874+
7.04.42 12-Nov-2018 - Added support for gage firmware update when connected to PosiSoft Desktop version 4.4.1 or greater
7.04.41 30-Oct-2018 - Added Max Thick Mode for PosiTector 200 probes - ideal when only total thickness of a coating sytem is required
7.04.40 27-Sep-2018 - Added additional USB stream functions for PosiTector UTG probes
7.04.39 20-Sep-2018 - Improved performance for PosiTector 6000 FNDS probe on small diameter parts and when a Zn Zero is required
7.04.38 7-Aug-2018 - Fixed issue which may cause gage to power off when connecting PosiTector PC probes
- Miscellaneous updates and fixes
7.04.37 19-July-2018 - Added USB serial stream mode for PosiTector UTG M and PosiTector SPG probes
- PosiTector PC: fixed issue which may cause gage to power off when in memory mode
- Miscellaneous updates and fixes
7.04.36 11-June-2018 - Added support for PosiTector BHI Barcol Hardness Impressor
- Added Zero control to USB to Serial API
7.04.34 15-Mar-2018 - Date/time now displays within PosiTector main menu
- Added adjustment for temperature emissivity - PosiTector DPM IR probes
- Miscellaneous updates and fixes
7.04.33 5-Mar-2018 - Added support for PosiTector DPM IR probe
- Miscellaneous updates and fixes
7.04.32 22-Feb-2018 - Fixed issues which could cause gage to become unresponsive when pairing a PosiTector PC probe
7.04.31 13-Feb-2018 - Increased adjustment range for PosiTector 200 probes
- Misc. fixes/updates
7.04.29 30-Jan-2018 - Misc. fixes/updates
7.04.28 15-Jan-2018 - Added support for 64 bit WiFi passwords
- Misc. fixes/updates
7.04.26 16-Nov-2017 - Added keyboard stream mode
- Miscellaneous updates and fixes
7.04.23 20-Jul-2017 - Added support for PosiTector SPG TS concrete profile probe
- Miscellaneous updates and fixes
7.04.20 28-Mar-2017 - Miscellaneous updates and fixes
7.04.18 28-Mar-2017 - Added support for PosiTector DPMA and PosiTector DPMD probes
7.04.16 7-Dec-2016 - Added live transfer (stream) of readings over USB. For applications supporting serial capture
- Removed Black on White display mode
- Miscellaneous updates and fixes

NOTE: This release may consist of (2) updates and may require repeating the update process twice. The first upgrades the gages update software, the second installs the latest revision.
7.04.15 21-Nov-2016 - PosiTector DPM: Fixed erroneous memory full error when connected via USB for extended period of time (in Auto Log mode)
7.04.13 11-Oct-2016 - Miscellaneous updates and fixes relating to PosiTector UTG/SHD
7.04.12 28-Sept-2016 - Added language translations to support PosiTector SST Soluble Salt Tester
7.04.11 22-Sept-2016 - Added support for PosiTector SST Soluble Salt Tester probe
- PosiTector 6000 FNDS now allows storage of measurement with no Zinc present
- PosiTector DPM: wet bulb temperature (Tw) now saved in memory
- PosiTector DPM: added Auto Sync to WiFi menu
- Miscellaneous updates and fixes
7.04.09 17-Aug-2016 - Fixed issue with PosiTector 6000 FNDS probe data importing into PosiSoft
7.04.07 23-June-2016 - Miscellaneous updates and fixes
7.04.06 08-June-2016 - Added support for PosiTector SHD Shore Hardness Durometer
- Miscellaneous updates and fixes
7.00.03 17-May-2016 - Miscellaneous fixes/updates
- Added support for PosiTector 6000 FNDS probe
7.00.02 03-May-2016 -Added BLE (Bluetooth Low Energy) support for communication with smart devices (PosiTector App)
-Updated menu navigation
-Miscellaneous fixes/updates
7.00.01 08-Feb-2016 - Initial release

ADV Base (PosiTector Advanced models - Serial Numbers: 730,000 to 784,000)

Revision Release Date Release Notes
7.04.49 25-Jun-2019 - Added support for PosiTector UTG-P, UTG-CA, UTG-CLF probes
- Miscellaneous updates and fixes
7.04.48 22-May-2019 - Added WiFi Streaming support
- Miscellaneous updates and fixes
7.02.46 23-Jan-2019 - Increased maximum measurement range for PosiTector 6000 FXS probe to 2000 microns (80 mils)
- Miscellaneous updates and fixes
7.02.44 7-Jan-2019 - Miscellaneous updates and fixes
7.02.43 2-Jan-2019 - Added support for PosiTector UTG M probes with serial number 355,874+
7.02.39 20-Sep-2018 - Improved performance for PosiTector 6000 FNDS probe on small diameter parts and when a Zn Zero is required
7.02.38 7-Aug-2018 - Fixed issue which may cause gage to power off when connecting PosiTector PC probes
- Miscellaneous updates and fixes
7.02.37 19-July-2018 - Added USB serial stream mode for PosiTector UTG M and PosiTector SPG probes
- PosiTector PC: fixed issue which may cause gage to power off when in memory mode
- Miscellaneous updates and fixes
7.02.36 11-June-2018 - Added support for PosiTector BHI Barcol Hardness Impressor
- Added Zero control to USB to Serial API
7.02.34 15-Mar-2018 - Date/time now displays within PosiTector main menu
- Added adjustment for temperature emissivity - PosiTector DPM IR probes
- Miscellaneous updates and fixes

7.02.33 5-Mar-2018 - Added support for PosiTector DPM IR probe
- Miscellaneous updates and fixes

7.02.23 20-Jul-2017 - Added support for PosiTector SPG TS concrete profile probe
- Miscellaneous updates and fixes

7.04.20 27-Apr-2017 - Miscellaneous updates and fixes

7.02.15 21-Nov-2016 - PosiTector DPM: Fixed erroneous memory full error when connected via USB for extended period of time (in Auto Log mode)

NOTE: This release may consist of (2) updates and may require repeating the update process twice. The first upgrades the gages update software, the second installs the latest revision.

7.02.13 11-Oct-2016 - Miscellaneous updates and fixes relating to PosiTector UTG/SHD

7.02.12 28-Sept-2016 - Added language translations to support PosiTector SST Soluble Salt Tester

7.02.11 22-Sept-2016 - Added support for PosiTector SST Soluble Salt Tester probe
- PosiTector 6000 FNDS now allows storage of measurement with no Zinc present
- PosiTector DPM: wet bulb temperature (Tw) now saved in memory
- PosiTector DPM: added Auto Sync to WiFi menu
- Miscellaneous updates and fixes

7.02.09 17-August-2016 - Fixed issue with PosiTector 6000 FNDS probe data importing into PosiSoft


7.02.06 08-June-2016

- Added support for PosiTector SHD Shore Hardness Durometer
- Miscellaneous updates and fixes

7.02.04 01-June-2016 - Miscellaneous fixes/updates
- Added support for PosiTector 6000 FNDS probe


5.17.00 17-May-2016 -Miscellaneous updates/fixes


5.16.00 03-May-2016 -Miscellaneous updates/fixes


5.15.00 04-Jan-2016 -Miscellaneous updates
-Added wet bulb temperature to JSON file


5.14.00 01-Apr-2015 -Added support for PosiTector RTR-P probe

5.13.00 24-Feb-2015 -Added support for PosiTector SPG-CS probe

5.12.00 17-Feb-2015 --Miscellaneous fixes/updates

5.11.00 26-Jan-2015 --Added support to display millimeter (mm) for PosiTector 6000 FT/FTS/FNTS probes

5.10.00 26-Jan-2015 --Added support for PosiTector 6000 FXS Xtreme probe

5.08.00 29-May-2014

Advanced models with serial numbers greater than 730,000 only:
-Added support for Wireless Access Point feature

5.06.00 01-May-2014 -Fixed issue where PosiTector may not be found in PosiSoft 3.0 & PosiSoft Mobile when connected via WiFi
-Miscellaneous fixes/updates

5.05.00 17-Mar-2014 -Added support for PC (powder checker) probes
-Miscellaneous fixes/updates

5.01.00 19-Dec-2013 New probe interchangeability features...
-Hot Swap - change probes without powering down the instrument
-Probe Settings Retention: PosiTector remembers the stored settings of each probe that was attached
5.00.00 30-Oct-2013 -Added support for RTR (replica tape reader) probes
4.00.16 23-July-2013 -Miscellaneous fixes/updates (UTG probes)
4.00.14 10-July-2013 -Miscellaneous fixes/updates (6000 probes)
4.00.11 10-May-2013 -Added support for 6000 FNGS probe
-Fixed displayed range in Gage Info (200 probes only)
-Miscellaneous fixes/updates

4.00.09 07-Jan-2013 -Miscellaneous fixes/updates
4.00.08 12-Dec-2012 -Support for PosiTector 6000 FHXS Xtreme probe
4.00.06 29-Oct-2012 -Support for 200 (ultrasonic coating thickness) probes
3.01.05 08-Aug-2012

Advanced models with serial numbers greater than 730,000 only
-
Support for User Cal Adj feature within PosiSoft Desktop Manager
-Miscellaneous fixes/updates to WiFi support

3.01.04 17-July-2012 -Initial Release (WiFi support)

 

ADV Base (PosiTector Advanced models - Serial Numbers: 702,000 to 729,000)

Revision Release Date Release Notes
5.17.00 17-May-2016 -Miscellaneous updates/fixes


5.16.00 03-May-2016 -Miscellaneous updates/fixes


5.15.00 04-Jan-2016 -Miscellaneous updates
-Added wet bulb temperature to JSON file


5.14.00 01-Apr-2015 -Added support for PosiTector RTR-P probe

5.13.00 24-Feb-2015 -Added support for PosiTector SPG-CS probe

5.12.00 17-Feb-2015 --Miscellaneous fixes/updates

5.11.00 26-Jan-2015 --Added support to display millimeter (mm) for PosiTector 6000 FT/FTS/FNTS probes

5.10.00 26-Jan-2015 --Added support for PosiTector 6000 FXS Xtreme probe

5.08.00 29-May-2014

Advanced models with serial numbers greater than 730,000 only:
-Added support for Wireless Access Point feature

5.06.00 01-May-2014 -Fixed issue where PosiTector may not be found in PosiSoft 3.0 & PosiSoft Mobile when connected via WiFi
-Miscellaneous fixes/updates

5.05.00 17-Mar-2014 -Added support for PC (powder checker) probes
-Miscellaneous fixes/updates

5.01.00 19-Dec-2013 New probe interchangeability features...
-Hot Swap - change probes without powering down the instrument
-Probe Settings Retention: PosiTector remembers the stored settings of each probe that was attached
5.00.00 30-Oct-2013 -Added support for RTR (replica tape reader) probes
4.00.16 23-July-2013 -Miscellaneous fixes/updates (UTG probes)
4.00.14 10-July-2013 -Miscellaneous fixes/updates (6000 probes)
4.00.11 10-May-2013 -Added support for 6000 FNGS probe
-Fixed displayed range in Gage Info (200 probes only)
-Miscellaneous fixes/updates

4.00.09 07-Jan-2013 -Miscellaneous fixes/updates
4.00.08 12-Dec-2012 -Support for PosiTector 6000 FHXS Xtreme probe
4.00.06 29-Oct-2012 -Support for 200 (ultrasonic coating thickness) probes
3.01.05 08-Aug-2012

Advanced models with serial numbers greater than 730,000 only
-
Support for User Cal Adj feature within PosiSoft Desktop Manager
-Miscellaneous fixes/updates to WiFi support

3.00.04 01-June-2012 -PosiTector DPM: Fixed Trend Chart display issue
-Miscellaneous fixes/updates

3.00.03 26-April-2012 -UTG updates
3.00.01 13-April-2012 -Added support for UTG (ultrasonic thickness) probes
-Added Screen Capture feature - compatible with all probes
-Added memory summaries screen - compatible with all probes
-Miscellaneous fixes/updates
2.00.09 06-Mar-2012 -Added Batch Annotation with on-screen QWERTY keyboard
-Misc. updates and fixes for SSPC-PA2 (PosiTector 6000) and Smart Batch (PosiTector SPG)

2.00.06 29-Dec-2011 -PosiTector 6000: updated PA2 batch view, added axis labels to real-time chart
-PosITector SPG: SmartBatch now opens correctly when no readings exist in a batch (empty batches)
-Updated Dutch translations.
2.00.05 30-Sept-2011 -Added status and substrate data fields to the readings.txt file located within the PosiTector's USB Mass Storage drive.
2.00.04 27-Sept-2011 -Added support for SPG (surface profile) probes
-Updated Spanish and Korean language translations
2.00.03 09-Sept-2011 -Added support for DPM (dew point meter) probes.
-Improved power management to extend battery life
-Enhanced USB Mass Storage - faster initialization of PosiTector virtual drive when plugged into computer. -Updated German, Chinese, Czech, French, Dutch, Norwegian, Japanese and Italian language translations
-Updated help screens.
-Miscellaneous fixes/updates

1.00.52 04-Aug-2011 -Resolved periodic delay while measuring in Fast Mode
-Fixed: [Statistics Mode] A high value (9999) was erroneously displayed when using the (-) button to delete the last reading.
-Fixed: Bluetooth Printing of non-latin characters
-A probe disconnect icon will now display during power-up if a probe is not attached
-Added Icon overview help screen
-Miscellaneous fixes/updates

1.00.51 27-May-2011 -Enhanced button response
-Included Italian language help support
-Added Gage Serial Number to USB Mass storage index.html file

1.00.50 10-May-2011 -Multilanguage help support. Minor updates to IMO PSPC 90/10 mode. Miscellaneous fixes.
1.00.49 05-May-2011 -Updated menu translations for German, Chinese, Dutch, Spanish, Korean, Russian, Portuguese, Norwegian and Turkish.
-Updated DeFelsko logo in USB Mass Storage Reports
1.00.48 25-April-2011 -Miscellaneous fixes/updates
1.00.47 13-April-2011 -Initial Release



© 2024 DeFelsko Corporation. ALL RIGHTS RESERVED.