uparrow-iconp0chonk

PosiTest® HHD Verifier

PosiTest HHD Verifier standalone voltmeter (crest meter, jeep meter) for verifying the accuracy and operation of pulse type DC holiday detectors

Ideal for field/laboratory verification of the PosiTest HHD High voltage Holiday Detector

Green check graphic denoting that an item is in stock
In Stock
Same-day shipping if ordered by 2PM EST
PosiTest AT Verifier with PosiTest AT-A
Made in USA flag with black text below

Features

Image of the PosiTest HHD Verifier
simple icon

Simple

  • Ideal for field/laboratory verification of pulse DC holiday detectors
  • Wide measurement range: 0.5 – 35 kV
  • Simple two step operation
  • Lightweight/Portable — requires no external power source
  • Certificates of Calibration showing traceability to NIST included
  • Two year warranty
  • Made in USA
specifications icon

Specifications

Voltage Range
0.5 – 35 kV
Resolution
0.5 kV – 1 kV: 10 Volt Steps
1 kV – 35 kV: 100 Volt Steps
Accuracy
±5%
Operating Temperature
-20° to 60° C (-4° to 140° F)

Device comes complete with verifier, 1.8 m (6') ground wire, 3 AAA batteries, instructions, Long Form Certificate of Calibration traceable to NIST, two year warranty

Size: 43 x 5 x 5 cm (17" x 2" x 2")

Weight: 476 g (1.05 lbs.)

Easy Operation

1

Ensure that the ground lead is plugged into the PosiTest HHD Verifier and that the other end of the ground lead is connected to the ground lead of the high voltage holiday detector that is being verified.

2

Turn the PosiTest HHD Verifier on by pressing and releasing the power button. Once powered on, the verifier continuously monitors the voltage on the probe on the end of the verifier. The verifier will update the display when the probe is touching an exposed electrode of a holiday detector. The voltage displayed on the verifier should match the voltage displayed on the detector within the combined tolerance of both units.

F.A.Q.

plus-icon
minus-icon

What is the PosiTest HHD Verifier?

The PosiTest HHD Verifier is a calibrated voltmeter (crest meter, jeep meter) ideal for verifying the operating voltage of ALL Pulse type holiday detectors in the range from 500 to 35,000 Volts.

plus-icon
minus-icon

Is the PosiTest HHD Verifier necessary to use the PosiTest HHD High voltage Holiday Detector?

No. The PosiTest HHD features a built-in voltmeter (crest meter, jeep meter) with a traceable Long Form Certificate of Calibration. However, some standards call for a standalone voltmeter.